AutoDome Easy IP
Preparing the Wiring | en
19
Bosch Security Systems, Inc.
Installation Manual
F01U079609 | 1.0 | 2008.08
4.3
Alarm
The recommended optional alarm input cable is a 2-conductor,
18-22 gage cable, depending on the distance. Refer to the
wiring distance guide below.
Alarm connections
Follow the instructions in the table below to terminate the two
(2) alarm connections:
Wire color
Description
24 VAC operation
+12 VDC operation
Red
AC + (positive)
DC + (positive)
Orange
AC – (negative)
DC – (negative) (DC
common or ground)
Wire size
Maximum distance
AWG
mm
feet meters
22
0.644
500 152.4
18 1.024
800 243.8
Wire color
Description
Blue
Alarm Common
Violet
Alarm In