Appendix A: Wiring Summary
Standard
Reference
Description
F1
Feed 1, 24 VAC for optional washer
F2
Feed 2, 24 VAC for optional washer
AL1
Alarm 1 Input; triggered by external DC voltage
AL2
Alarm 2 Input; triggered by external DC voltage
AL3
Alarm 3 Input; triggered by external DC voltage
AL4
Alarm 4 Input; triggered by external DC voltage
Com
Alarm Common (ground)
O1
Output 1; Normally Open; Dry contact relay output
C1
Common 1; common for Output 1
O2
Output 2; Normally Open; Dry contact relay output
C2
Common 2; common for Output 2
GND
Video ground, black cable from coaxial termination cable
VIDEO
Video output, clear cable from coaxial termination cable
(BILINX protocol)
RS-485-1
Pelco D Protocol 300 to 19200 Baud 8 N 1 Tx channel
A
Data (connect to Peclo controller input Rx +)
B
Data (connect to Pelco controller input Rx -)
RS-485-2
Peclo D protocol, 300 to 19200 Baud 8 N 1 Rx channel
A
Data (connect to Pelco controller output TX +)
B
Data (connect to Pelco controller output TX -)
B+
B (OSRD protocol)
B-
Biphase - (OSRD protocol)
IR
Reference
Description
F1
Feed 1, 24 VAC for optional washer
F2
Feed 2, 24 VAC for optional washer
AL1
Alarm 1 Input; triggered by external DC voltage
AL2
Alarm 2 Input; triggered by external DC voltage
LNO
External IR Probe, Normally Open Contact
AGND
Alarm Ground & External IR probe common
O1
Output 1; Normally Open; Dry contact relay output
17
78
en | Appendix A: Wiring Summary