2 - PRESET POSITION
: 0000
1
3 - RELAY NR.
: 0000
2
4 - PUMP DELAY
: 0000
3
5 - WIPER DURATION
: 0000
5
6 - DELAY WIPER OFF
: 0000
2
Feature
Description
Default
Options
ENABLED
Enables the wiper function.
NO
YES, NO
PRESET POSITION
Enables the preset position to be
reached.
00001
00001 to 00250
RELAYS NR.
Enables the relay to activate for water
pump control.
00002
00001 to 00002
PUMP DELAY
The delay between the pump command
and when the wiper starts moving.
00003
00001 to 00050
WIPER DURATION
The amount of time that the wiper wipes. 00005
00001 to 00050
DELAY WIPER
The amount of time that the wiper wipes
without water.
00002
00001 to 00050
Alarms
The Alarms menu is used to set up the action and duration of the alarm when it is activated.
MOTION PARAMETERS MENU
ALARM MENU
1 - SPEED
> 1 - ACTION:
: SCAN
2 - LIMITS
2 - NR.
: 1
3 - PRESET/PATROL/AUTOPAN
" 3 -
4 - WIPER-WASHER
4 - SHOW MESSAGE
: N
" 5 - ALARMS
5 - DURATION
: 00000
6 - TXT: Test Alarm 1
12.3.5
High-Speed Positioning System
(HSPS)
Configuring the System | en
63
Bosch Security Systems, Inc.
Operation Manual
2013.11 | 5.2 | F.01U.291.981