For DIP switches (Reference 1-3 , page 42), when the rocker is down the switch is OFF or
represents the logical value “0”; when the rocker is up, the switch is ON, with logical
value “1.”
–
For DIP switches (Reference 4-5 , page 42), when the rocker is up the switch is OFF or
represents the logical value “0”; when the rocker is down, the switch is ON, with logical
value “1.” The white rectangle represents the position of the rocker.
Pelco D Baud Rate
Dip switches 4, 3, and 2 are used to set the communication rate of the device according to the
table below:
Dip Switch 4 Dip Switch 3 Dip Switch 2 Dip Switch 1 Baud Rate
Off
Off
Off
Off
300 Baud
On
Off
Off
Off
600 Baud
Off
On
Off
Off
1200 Baud
On
On
Off
Off
2400 Baud
Off
Off
On
Off
4800 Baud
On
Off
On
Off
9600 Baud
Off
On
On
Off
19200 Baud
Protocol
There is no need to set any particular protocol, the UPH is auto-sensing. The protocols
supported are:
Protocol
Baud Rate
Menu Setup (OSD)
Pelco D
Selectable (8N 1)
Preset 95
Biphase and Bilinx
Auto
AUX-On 200
Setting the Address
You can set the address for the UPH address using the Address switched (see item 3 in , page
42).
Notice!
The highest addres using the Bosch OSRD protocol is 998. The highest address using the
Pelco D protocol is 255.
Binary code is used to select the address using the 10 DIP switches. The up position
represents binary value “1”, while the down position represents binary value “0”.
To convert a decimal address to a binary address, use the following technique.
–
Assign a binary value to each DIP switch, starting with a binary value of “1” for DIP switch
1. If the DIP switch is “on” then the number associated with the switch is stored.
11.1
11.2
11.3
High-Speed Positioning System
(HSPS)
Configuring the Device | en
43
Bosch Security Systems, Inc.
Operation Manual
2013.11 | 5.2 | F.01U.291.981