702_58300000170749_ara_en_c
Page 66 of 82
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary
information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
6.1.4
Error code / troubleshooting chart
Error
Code
Description
Part
DW Symptoms
(seen during wash cycles)
Solution
E:00
No errors
No errors
E:01
Faulty pump relay
P
o
w
e
r m
o
d
u
le
Wash cycle abruptly ends with
Sanitized
LED lit
Replace power module (located in base).
E:02
Faulty heater relay
Dishwasher runs without heating / heater error
E:05
Faulty water switch relay
Water switch runs continually
E:06
Door latch Hall sensor not
detected
H
al
l sen
so
r
DW won’t run &
Clean
LED is flashing
Align door latch above Hall sensor
(inside inner door)
Defective door latch Hall sensor
Check continuity / connections between door switch
(q2)
and power module.
With door closed, measure voltage across door latch Hall
sensor connector. If > 10V, replace Hall sensor. If < 10 V,
replace power module.
E:08
Heat pump detects low water
level
W
at
er
i
n
let
Not heating
Check water supply & repair any leaks. Check for kinks in
inlet hoses. Turn over pots / bowls collecting water.
Check continuity between water inlet valve
(k2)
and power
module.
Measure voltage across water inlet valve terminals
(k2)
during step 1 of customer service test program. If ≈ 120V,
replace water inlet valve. If not ≈ 120V, replace power
module.
E:09
Faulty heater circuit (open -
circuited)
H
eat
p
u
mp
Check continuity between heat pump heating element
(e1)
and power module.
Measure heat pump heating element
(e1)
resistance, which
should be ≈ 8.9Ω @ room temp. If not, replace heat pump.