5.7.1
To remove aqua sensor
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers
.
1.
Remove parts for bottom front access
– section 5.1.4.1.
2. If needed for access,
remove power module
– section
5.3.2.2
3. Lift up housing latch, twist aqua sensor counter-clockwise
(ccw) and pull aqua sensor out from sump.
5.7.2
To install aqua sensor
1. Insert aqua sensor into sump with pc board vertical, then
twist clockwise (cw).
TIP
: Apply some rinse-aid onto the aqua sensor O-
ring to lubricate it for easier installation.
5.8
Water inlet control
The water inlet control is easily accessed from the left side of the
dishwasher. It includes a condensation vent, so there’s no
separate condensation tube. The water inlet, sump and drain
hoses all connect to it.
Tools needed: T20 Torx & #2 Phillips screwdrivers and pliers
.
1.
Disconnect & pull out dishwasher
– section 5.1.5.1.
2. Remove lower rack
(below left)
. If more space is
needed, remove the upper rack as well.
3. Unscrew condensation vent cap ccw (counterclockwise)
from inside of tank
(below right)
.
4. Loosen hose clamp
(1)
from water inlet hose
(2)
and pull
water inlet hose from water inlet
(3, below)
.
5. Pull out drain
(4)
and sump
(5)
hoses
from water inlet
control
(below)
.
1
2
3
4
5