DSS user interface
4–15
1070 066 091-102 (01.08) GB
4.6.4
Resetting errors (class 1)
If errors of diagnostics class 1 have occurred, the drive will be interlocked
(optimum shut-down with subsequent torque removal).
L
In order to unlock the drive when the error has been eliminated,
D
set bit 3 in the PROFIBUS control word P-0-2800, or
D
reset the error in the DSS.
To reset the error in the DSS, open the logbook for diagnostics class 1 errors
(cf. section 8.1). The error history is listed by the error codes in the logbook.
Alternatively, open the ”Module error display” by
D
menu sequence DIAGNOSTICS
"
MODULE ERROR DISPLAY, – or –
D
Icon bar: Click on
Locate the cause of the error and eliminate all errors. Then, enter the com-
mand ”Reset device error” by
D
Menu sequence CONTROL
"
RESET DEVICE ERROR, – or –
D
Icon bar: Click on
– or –
D
"
RESET DEVICE ERROR in the ”Overview” window.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01