Diagnostics
8–2
1070 066 091-102 (01.08) GB
8.2
Drive status
The display will show
dynamic
information on
D
drive status: diagnostics message in plain text
D
values of max. 4 selectable parameters
D
condition of the 4 least significant bits of parameter P-0-2003
D
status of ”Drive ON”, ”Drive enable”, and ”Drive start”
D
current operation mode
D
changes in ”diagnostics class 1” to ”diagnostics class 3” parameters
(S-0-0011 to S-0-0013)
Displaying cyclic data
L
Select the menu sequence:
D
DIAGNOSTICS
"
MODULE STATUS DISPLAY, – or –
D
"
MODULE STATUS DISPLAY in the ”Overview” window.
Drive status in plain text as per
S-0-0095.
Display of max. 4 parameters. For
configuration, cf. page 8–3.
For displaying parameters in sepa-
rate windows, refer to section 8.4
page 8–5.
Display of 4 digital outputs
(P-0-2003).
For configuration, cf. P-0-2002 and
section 5.2.2, page 5–5.
Also refer to section 8.3.
For updating frequency of the data, refer to page 8–3.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01