Diagnostics
8–4
1070 066 091-102 (01.08) GB
8.3
I/O signals
The DSS shows you
D
the signals assigned to the digital inputs and outputs of the module, and
D
the current status of these signals.
For the assignment of individual signals to the digital inputs and outputs of
the module, please refer to section 5.2.2 on page 5–5 ff.
L
Select the menu sequence DIAGNOSTICS
"
I/O SIGNALS.
Example of a display for a drive with an analog interface:
Display showing all input sig-
nals configured in P-0-2000.
The current status of the sig-
nals is derived from P-0-2001.
Display showing all output sig-
nals configured in P-0-2002.
The current status of the signals
is derived from P-0-2003.
A HIGH level is indicated by a
green
LED, a LOW level by a
gray
LED by the
DSS.
LEDs not followed by a text indicate that the corresponding bit has not been
assigned to a signal in P-0-2001.
The data display is updated in the intervals set for the ”Module status