Series commissioning
6–1
1070 066 091-102 (01.08) GB
6
Series commissioning
During series commissioning, all data backed up from the FEPROM after ini-
tial commissioning of a drive are loaded to and saved in all other drives.
.
If your application involves drives with different settings, initial com-
missioning has to be performed separately for every single setting.
L
Make sure that all works described in section 2.1 and 2.2 have been properly
executed for each drive to be commissioned.
L
Establish communication between the first drive to be commissioned and
6.1
Loading files
L
Make sure that all required *.scs files are available for the drive currently con-
nected to the DSS. These may be *.scs files
D
generated when setting the basic parameters (cf. page 5–1 ff.)
D
generated when programming the extended parameters (cf. page 5–4 ff.)
D
generated during controller optimization (cf. page 7–2 ff.)
L
If you have created *.scs files for the individual commissioning steps using
the ”IDN Backup” function, you only have to transfer the *.scs file that was
created last (because ”IDN backup” always saves
all
parameters contained
in the FEPROM).
If you saved parameters ”one by one” in *.scs files during commissioning,
you should transmit the files to the drive in the same order in which they were
created:
1. Select the desired *.scs file by
D
the menu sequence FILE
"
OPEN – or –
D
Icon bar: Click on
– or –
D
"
DSS FILE in the ”Overview” window.
2. Load the selected ”.scs file into the editor by clicking on ”Open”.
.
Several files may be opened in parallel. Each file will then be dis-
played in a separate editor window.
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01