8.2 Checking the hydraulic supply
Before commissioning the hydraulic power unit, check
•
the hydraulic hose lines for damage;
•
the tight seat of the fittings; connection to hydraulic power unit and to P/T distributor
•
as to whether any components are damaged;
•
as to whether all attachment parts are properly connected;
•
that the tank is filled. Related details are contained in the following chapter.
8.3 Filling the oil tank
In this connection, observe the specifications for the hydraulic fluid to be used.
These specifications are contained in chap. 13.
If other hydraulic fluids than those described in chap. 13 are to be used, coordination with
the Bosch Rexroth service is necessary before any use.
Prerequisite for first filling, refilling, oil exchange:
Ensure that the hydraulic power unit is switched off and that the mains plug is
pulled out.
Make sure that the work station is depressurized.
Keep a funnel ready.
For the hydraulic fluid to be used, please refer to chap. 13.
Summary of Contents for Rexroth WS200
Page 1: ...WS200 work station Operating instructions DCA DE 000151 10 2013 Replaces English ...
Page 85: ...Appendix 85 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 86: ...86 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 87: ...Appendix 87 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 88: ...88 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 89: ...Appendix 89 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 90: ...90 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 91: ...Appendix 91 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG 15 2 Declaration of conformity ...