16/92
General information on damage to property and damage to the product
Bosch Rexroth AG
, WS200, DCA_DE_000151/10-2013
3
General information on damage to property
and damage to the product
The warranty only applies to the delivered configuration.
The claim to warranty expires if the product is incorrectly assembled, commissioned and
operated, not used as intended and/or handled improperly.
NOTICE
Danger due to improper handling!
Damage to property!
The product may only be operated according to section 2.2 "Intended use".
Avoid impacts against functionally relevant areas (e.g. sealing surfaces) and attachment
parts (e.g. control system, accumulator, valves).
Mixing hydraulic fluids!
Damage to property!
Any mixing of hydraulic fluids of different manufacturers and/or of different types of the
same manufacturer is generally not admissible.
Contamination by foreign particles!
Early wear and malfunctions!
During assembly, provide for cleanliness in order to prevent foreign particles from getting
into the hydraulic lines and causing wear or malfunctions.
Before commissioning, ensure that all hydraulic and mechanical connections
have been made.
During filling, filter the hydraulic fluids using a suitable filter system in order
to minimize the solid particle contamination in the system.
Pressurized and live system!
Damage to property!
Do not disconnect lines, connections or components as long as the hydraulic power unit
and the training set-up are under pressure.
Do not disconnect lines, connections or components as long as the pneumatic training set-
up is pressurized.
Do not disconnect electric connections as long as the hydraulic power unit and the training
set-up are connected to the power supply.
Incorrect setting of the pressure relief valves and the pressure switches of the hydraulic
and pneumatic components!
Damage to property!
The hydraulic form of the work station may only be operated with a max. pressure
of 60 bar.
The pneumatic form of the work station may only be operated with a max. pressure
of 6 bar.
Hazard for the electrical equipment due to high electric currents!
Damage to property!
Make sure that excess-current protection equipment is available.
Summary of Contents for Rexroth WS200
Page 1: ...WS200 work station Operating instructions DCA DE 000151 10 2013 Replaces English ...
Page 85: ...Appendix 85 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 86: ...86 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 87: ...Appendix 87 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 88: ...88 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 89: ...Appendix 89 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 90: ...90 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 91: ...Appendix 91 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG 15 2 Declaration of conformity ...