Commissioning
8.1 Setting the WS200 work station up
Proper execution of the set-up requires that:
•
the delivery, the transport and the unpacking according to chapter 6 " Transport and
storage" have been properly completed,
•
all parts required are within reach and functional,
•
required aids (e.g. oil funnel for filling the tank) are available.
Consider the following aspects before the final set-up:
Make sure that the clearance area required for the work station and the safety
clearances to fixed installations are available (requirements see fig. 1).
The place of installation is suitable with regard to load-bearing capacity of the
installation space. In order to evaluate the load-bearing capacity, you should assume
a weight of at least 200 kg. The weight refers to a WS200 work station, completely
equipped (2x grid, grooved plate, 2x hydraulic power unit) including training set-ups at
both grids.
For a firm stand of the work station, the place of installation should be sufficiently level.
Make sure that an electrical connection is available.
For the operation, earthed industrial mains are required (TN-S mains type) 1 x AC 230 V
(±10 %), 50-60 Hz.
Make sure that there is sufficient lighting at the set-up location. For the teaching, an
illumination of at least 500 lux (based on DIN EN 12464-1, illumination at workplaces)
is recommended:
Observe the following aspects after the set-up:
As protection, lock the locking devices of the transport rollers.
Water protection with hydraulic system:
The oil pan of the base frame of the WS200 work station has a capacity of 17 liters. Thus,
the contents of two hydraulic power units of type ANTRIEBSAGGREGAT TS-WS200
220V/50HZ 1X can be collected. Dispose of any supplies and auxiliary materials spilled and
used as prescribed pursuant to the country-specific legal provisions. Also observe the
information in chap. 15.1.
NOTICE
Danger due to irregularities, variations, faults, defects during the set-up or the test!
Risk of damage!
Do not put the work station into operation and/or take it out of operation without
undue delay.
Determine the cause and remedy the defect.
Replace the defective component.
Preparations
for set-up
Set-up
Summary of Contents for Rexroth WS200
Page 1: ...WS200 work station Operating instructions DCA DE 000151 10 2013 Replaces English ...
Page 85: ...Appendix 85 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 86: ...86 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 87: ...Appendix 87 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 88: ...88 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 89: ...Appendix 89 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG ...
Page 90: ...90 92 Appendix Bosch Rexroth AG WS200 DCA_DE_000151 10 2013 ...
Page 91: ...Appendix 91 92 DCA_DE_000151 10 2013 WS200 Bosch Rexroth AG 15 2 Declaration of conformity ...