Servodyn-D frequency inverter displays
4.8
Servodyn-D frequency inverter displays
4.8.1
Status/warning displays
LED
Status
Action
FG
Axis enable external
if
D
24 V at X06.3/4 (FG)
–
FGI
Enable internal
if
D
24 V at X06.3 (FG)
D
Central enable by VM present
D
no error
–
3-digit 7-segment display
computer has
been booted
TEMP
STA
Operating display:
D
STA is present if:
– computer has been booted
– no errors
Temperature status:
D
TEMP is present if:
Temperature of the heat sink or the
motor (with active bimetal function) is
within the permitted range.
D
TEMP relay is closed
–
If no display (temperature exceeded):
D
Check air supply, fan
D
Reduce cycle frequency or load
D
Select motor with higher rating
D
Verify bimetal setting
You can read various operating data from the 7-segment display:
D
Press <D> key in the basic display.
D
Select the ’A’ display function with the < > or < > keys.
D
Press key <D>.
D
Select the desired operating display with the < > or < > keys,
e.g. A00 (actual output frequency).
D
Press key <D>.
D
The display shows the current operating data.
D
Jump back to the operating data level by simultaneously press-
ing the < > and < > keys.
D
You may now select the next operating display with the < > or
< > keys, e.g. A08.
D
Further procedure as described above.