4–28
Electric Drives
and Controls
Bosch Rexroth AG
Servodyn-D 1070 066 032 / 03
PROFIBUS-DP errors
4.6
PROFIBUS-DP errors
Displays flash
alternately.
Error
The drive has switched off.
Action
Initialization error
Incorrect parameterization data
D
Check structure of the parameterization
data
(refer to “Servodyn with PROFIBUS-DP
Interface” manual)
Initialization error
Configuration data does not match the de-
sired configuration
D
Check whether the drive mode from the
parameterization data matches the tele-
gram configuration
4.7
DMA computer errors (without SERCOS interface)
Displays flash
alternately.
Error
The drive has switched off.
Action
up to
CPU program execution errors
H01 dc Power failure (also refer to F 36)
H02 stack overflow
H03 stack
underflow
H04 undefined CPU code
H05 undefined protected command
H06 inadmissible word instruction
H07 inadmissible jump
H08 inadmissible bus control
D
Contact Rexroth technical service
D
Replace module
up to
CPU computing errors
H09 integer overflow
H10 floating overflow
H11 floating underflow
H12 division by zero
H13 undefined floating number
H14 integer/floating conversion error
H15 floating point stack overflow
H16 floating point stack underflow
D
Check last parameter changes made
before error occurred
D
Contact Rexroth technical service