4–2
Electric Drives
and Controls
Bosch Rexroth AG
Servodyn-D 1070 066 032 / 03
VMA..KR, VMA..B,C,D,F status displays
4.2
VMA..KR, VMA..B,C,D,F status displays
LED
Status
Action
AE
Drive On
LED lights up at 24 V at X06.7 (AE)
–
FGI
Enable internal
if
D
24 V at X06.7 (AE)
D
no error
–
Multi-digit displays flash
alternately.
Normal operation (NO)
Standard ready display
–
Special operating mode (SO)
Operating mode for open safety door where
standstill monitoring of the drives is still active
at maximum energy supply.
–
Intermediate circuit not yet discharged
Alternate flashing while DC link voltage >50 V
Wait for a discharge time of 5 minutes and
then check the DC link at the DC measuring
sockets for zero voltage.
DANGEROUS ELECTRICAL VOLTAGE
Before dismounting the modules, wait for a discharge time of 5
minutes and check the DC link at the DC measuring sockets for