Installation 61/78
RE 66170-B/2019-05-15, Control block SB24/34, Bosch Rexroth AG
7.6.7 Electric connection of the control block/control block segment
NOTICE
Negative effect on function due to incorrect plug-in connections!
Only the plug-in connections specified in the data sheet/offer drawing may be used
for electrical connection.
▶
Observe the installation specifications of the manufacturer of the plug-in
connection.
▶
Before commissioning, check to see whether the voltage in the power supply
matches the information in the offer drawing and whether the total current to
be expected is less than or the same as the load capacity of the power supply.
▶
Do not connect live plug-in connections. The assembly process may only be
repeated 10 times.
The machine/system manufacturer is responsible for electric control layout.
Electrically controlled control blocks/control block segments must be connected in
accordance with the electrical circuit diagram of the machine.
For control blocks/control block segments with electrical control and/or mounted
sensors, please comply with the details given in the data sheet and the offer
drawing, e.g.:
• Permissible voltage range
• Permissible current
• Correct pin assignment
Exact details on the correct assignment of the connector, the type of protection
and the appropriate mating connector can also be found in the data sheet and
the offer drawing. The mating connector is not included in the scope of delivery.
To connect the control block/control block segment to the machine electronics,
proceed as follows:
1.
Deenergize the plug-in connections at the control block/control block segment.
2.
Before establishing the connection, check the connector and all seals for damage.
3.
Establish the electrical connection of the control block/control block segment.
Procedure