26/78
About these products
Bosch Rexroth AG, Control block SB24/34, RE 66170-B/2019-05-15
5.3.9 Connecting plate for variable pump (C6)
Table 13: External ports
Position
Designation
Information
Pressure reducing valve control port
optional
Inlet port
optional
Return flow
optional
LS signal input
optional: 1, 2, 3, 4, 5
LS signal output
EHS pilot oil pressure diagnosis
optional
, ,
Tie rod bore with thread
Block mounting thread
Table 14: Internal functions
Position
Designation
Information
Shuttle valve with spring pretension
optional
Pressure relief valve
optional
Rx-R non-return valve
optional
Pressure reducing valve
optional
Pressure reducing valve switchable solenoid
optional
Threaded plug
optional
The
C6
connecting plate is used for SBx4 blocks with or without central connecting
plate.
Shuttle valve with spring pretension :
Discharges the higher LS pressure from the
block-internal channel Y and
to port
. The spring pretension prevents pressure
build-up in
if port
is not occupied.
Pressure relief valve :
Limits the pressure at port
and indirectly also the
pressure in the block-internal
P
line.
NOTICE!
The pressure relief valve with its short response time and low flow is
applied for limitation of the pressure peaks in the supplied flow.
Application
Internal function