60/78 Installation
Bosch Rexroth AG, Control block SB24/34, RE 66170-B/2019-05-15
7.6.6 Customer-specific coupling connection
Item
Designation
Use
Information
Number
Directional valve
Coupling housing
O-ring
Port A and B
24.5 × 2.15
2
Socket-head screw
M6
4
The coupling connections are customer-specific and deviate from the illustration.
Installation of customer-specific coupling flange:
1.
Insert the O-rings into directional valve ports
and
.
2.
Align coupling housing with flange surface to the directional valve .
3.
Align coupling housing and the mounting bores with the coupling mounting
threads in directional valve .
4.
Tighten the coupling housing with the four socket-head screws at the
coupling port of directional valve .
5.
Tighten socket-head screws . Tightening torque
M
A
= 11
+1
Nm.