Technical Data of the Connection Point
View
Identifica‐
tion
Function
+24V
Power supply
Connection to neighboring devices with contact bars from ac‐
cessory HAS01.1
0V
Reference potential for power supply
Connection to neighboring devices with contact bars from ac‐
cessory HAS01.1
Screw connection
M6 thread at device (terminal block)
Unit
Min.
Max.
Tightening torque
Nm
5,5
6,5
Power consumption
W
P
N3
(see technical data)
Voltage load capacity
V
U
N3
(see technical data)
Polarity reversal protection
Within the allowed voltage range by internal protective diode
Current carrying capacity "looping through" from 24V to 24V, 0V to 0V
(contact bars in scope of supply of accessory HAS01)
With contact bars -072
A
220
Fig.5-8:
Function, Pin Assignment, Properties
Connection Diagram
A
Cable (to source of control voltage supply)
B
Contact bars
Fig.5-9:
Connection Points and Connections of Control Voltage
Notes on Installation
Requirements on the connection to the 24V supply:
Bosch Rexroth AG
DOK-INDRV*-HMS02*UL***-IB03-EN-P
Rexroth IndraDrive Drive Controllers Power Sections HMS02
34/67
Instructions for Use