Pneumatically connecting the DA 2/150-E damper
WARNING
High pneumatic pressure!
Risk of serious injury or death.
Switch off the compressed air supply to the relevant system component before
installing, removing or connecting the product to the pneumatic system.
Secure the system against being unintentionally switched on again.
• For the compressed air and operating pressure specifi cations, see page 64.
Fig. 16:
562 240-08
Ø 6x1 mm
l < 800 mm
4-6 bar
P
R
Pneumatic diagram for the DA 2/
150-E
damper
Connect the damper to the
compressed air supply.
Control sequence:
• enabling the workpiece
pallet to retract in the
HQ = enabling the damper
(pressure pulse, damper
extends).
Assembly 29/72
3 842 562 241/2019-04, MIT: HQ 2/U-H,
Bosch Rexroth AG
EN
GLISH