Fig. 8:
1
)
A
B
E
O
L
N
G
M
H
J
K
D
C
F
3 842 559 611
B
(2x)
A
(1x)
C
(3x)
F
(3x)
D
(3x)
E
(3x)
H
(2x)
J
(2x)
K
(2x)
G
(2x)
L
(2x)
M6x14
M
(2x)
N
(2x)
O
(2x)
M6x14
562 240-51
b
L
= 240 mm
b
L
SW4
M
D
=7 Nm
SW4
M
D
=7 Nm
M
D
=1 Nm
2x
T20
M
D
=2,5 Nm
2x
T20
Installing the position monitoring device, b
L
= 240 mm, upper position / lower position
Required accessories
•
3 842 548 585,
fastening kit
HQ 2/U-H
(included in the scope
of delivery)
b
L
= 240 mm
upper position/lower
position
1.
Install the switching fl ag
(L, M, N, O)
2.
Install the sensors
1
)
(A, B, C, D, E, G, H, J, K)
3.
After you have
pneumatically
connected the HQ 2/U-H
(see page 31):
set the sensors.
1
)
3 842 549 814
Not included in the scope of
delivery!
22/72 Assembly
Bosch Rexroth AG
, MIT: HQ 2/U-H, 3 842 562 241/2019-04