18/27
Bosch Rexroth Canada I March 2021 ı Revision 3.0
‘
R
’ –
Forward, ‘
R
’
- Reverse
2 digIn (Junction Box or CANIO board)
All booms must be open for nulling
Button color is RED when boom is open
Junction Box V1-B
Conveyor Forward
Junction Box V1-A
Conveyor Reverse
Junction Box V2-B
Spinner Forward
Junction Box V2-A
Spinner Reverse
3.4 3Boom Anti-ice (DLA)
This configuration is a dedicated 3 Boom Anti-ice system. It requires 3 digital inputs (junction box or
CANIO board) and 3 digital outputs for boom control.
To configure valve outputs it is highly recommended to use AUTONULL.
3.5 Dual Spinner
This feature supports a single or dual spinner operation. It requires a digital input to switch on/off dual
spinner function.