15/27
Bosch Rexroth Canada I March 2021 ı Revision 3.0
Material Names:
Select name from list
Click to popup keypad
Enter to save
Unit of Prewet Rate:
Liter/Ton
Gallon/Ton
Unit of Anti-ice Rate:
Liter/Lane.Km
Gallon/Lane.mi
STEP 2
Dial to 2
nd
or 3
rd
position for
decent flow
STEP 1
Ensure system safe to run
Continue if you have a
container ready and
sufficient liquid
throughout the calibration
process
2.5.4
Prewet and Anti-icing Material Setup
Tap on the prewet material icon
or anti-ice material icon
to configure materials desired. It
supports 4 prewet and 4 anti-ice materials, and 9 application rates and a blast rate for each material.
2.5.5
Prewet and Anti-icing Material Calibration
1.
Prepare a container to catch liquid discharged
2.
Make sure sufficient liquid in the tank and the system is safe to run
3.
Press ‘START’ to proceed, and follow the instruction on the screen