8
This mode utilizes the ground speed sensor only to regulate the amount of material that will be dispensed off the
vehicle. There are 9 configurable application rate settings available. The display will show “O” on the screen.
This is just for a single output. This mode will allow the operator selection of any combination of three outputs.
--- 3 boom closed loop
This mode utilizes both the flow meter and ground speed sensors to regulate the amount of material that will be
dispensed off the vehicle. There are 9 configurable application rate settings available. The display will show “C”
on the screen. This is just for a single output. This mode will allow the operator selection of any combination of
three outputs.
6.2
Null
1. Press
ENTER
to null manually and it starts with minimal value immediately
2. Use up and down arrows to adjust speed so that the motor just begins to turn
3. Press to end “Min” value editing and switch to the maximum value
4. Do the same for “Max” except adjust the motor to a safe maximum speed or until the RRM readout stops to
increase.
6.3
Autonulling
The nulling of the solenoids for minimum and maximum values can also be accomplished automatically.
Press the
ENTER
to start and the text “Autonulling” will flash on the screen during procedure.
Autonull will ends after recording the nulling values.
7
MATERIAL CONFIGURATION
There are four materials for liquid. Within the valves configuration page, the right side is for the corresponding
material configuration.
Using or move from DEICE configuration to material configuration.
RECIR: 90%