4
3
AUTHORIZATION VERIFICATION
To set up the CS-610, either a security USB or a password is needed according to the setting of feature LOCK,
this is to prevent unauthorized personnel from making adjustments to the system.
Once press the ‘SETUP’, it goes to the screen to require a security USB key or the input of the password. If it is
password verification, the screen will look like that:
The most right digit stays bright while the rests are dim, pressing keypad of left or right arrow to choose digit and
up/down arrow to change character (This also applies to the settings of other features). After that, press
ENTER
to confirm the input. The default password is 000000, user can change this password once in the setup screen.
4
SYSTEM CONFIGURATION
If the password is correct or program key is present, the setup screen will show on:
Press Up/down arrow to navigate to the different feature and the symbol
*
will mark the active line in front. Press
ENTER
to edit/select settings and some may also have a sub menu
CHG
to do edit (see example of the editing
of REGN below).
Press
NPAGE
to go to the next screen and
PPAGE
to the former one.
4.1
Setting the Region Name and Truck ID
REGN: To edit the REGION and TRUCK name
Version number
V.X
Please Enter Code
Code: 0 0 0 0 0 0
TOTAL SETUP MISC XXXXX ENTER
CHG
FINISH
REC:AUTO
Se
t
REC:AUTO
Se
t
BSW:N
BSW:N