14
Turn the dials until the desired speed is achieved. Press
QUIT
to exit unload mode. Moving the vehicle will
suspend the unload process. It will automatically resume when the truck is stopped again.
12
SPREADING SCREEN
When truck is moving, system will display spreading screen.
Press
STAT
will go to the diagnosis screen which displays the power voltage, actual flow meter frequency and
rate.
13
PAUSE/RECIRCULATE
If recirculation is disabled in setup:
Press down the encoder knob to pause and press again to resume spreading. If paused when unit shut down, it
will be paused on next boot.
If recirculation is manual in setup:
With no ground speed, press the down arrow on the operator screen, then press RECIR to enable recirculation.
When there is ground speed, it will disable recirculation. It will then need to be re-enabled the same way.
If recirculation is auto in setup:
Whenever the pause button is pressed, recirculation is enabled. When the system is un-paused, it resumes
normal spreading.
Remote pause optional by connecting a momentary switch to the digital inputs on the sensor cable.
It can be activated/deactivated in parallel either from the knobs or remote switches.
ON
ON
40kmh
STAT
QUIT
HZ: 0
RATE: 0
VOLTAGE : 12V