9
7.1
Material Name
Press
ENTER
to choose different liquid material.
Use up/down arrow to view each material’s settings and press
FINSH
to select the material.
If
CHG
is pressed, system will start to edit the material name which is consist of 4 characters.
After finish editing the material name then press
DONE
.
7.2
BLAST RATE
BLAST: This is not applicable to the CS610.
7.3
APPLICATION RATES
RATE: There are 9 settings of the application rate for each material when the conveyor works in open or close
loop.
Press
ENTER
and
then
up/down
arrow
to browse the rate setting values, and press
CHG
to edit the current
rate value.
7.4
PLS/LT or PLS/GAL
Enter the pluses per liter or gallon if known.
Note: This number will automatically be generated as a result of the weight calibration process (Autocal) or input
manually.
7.5
RECIRCULATE
Enter percentage of output when recirculation is running.
7.6
AUTOCAL
Here is the place to do the material calibration.
1.
Place an adequate catch container under the spreader discharge chute.
2.
Make sure that sufficient material in the hopper and the system is safe to run.
3.
Set gate position.
4.
Press
ENTER
to proceed.
5.
Turn CONV knob to run.
6.
Press
FINSH
when desired amount is reached.
CHG
FINISH
RECIR: 90%