13
-
Make sure that the vehicle is stationary (ground speed = 0)
-
Press UP and DOWN buttons to adjust simulated ground speed.
-
Under the simulation mode, the system still counts the spreading information into log, so please clear
that by resetting screen totals and retrieving logging data with USB.
9.2
Material change
Press the down arrow, then press once more to enter the sub, sub menu. If MAT is there, Press it to enter
the material change screen.
Press
SOLID
to change solid material.
A reminder screen of the calibrated gate of new solid material will last for 5 seconds.
10
ERROR MESSAGES
A beep will come on for 4 seconds when an error occurs, then goes off. Some error codes show on the screen
first and come back on 3 minutes later if it is not resolved, while others stay on the screen until power cycle or
resolved.
Error Messages
Suggested Solution
Cycle power Needed?
BLAST2LONG
Turn off blast
No
OVERSPEED
Slow down, reset max speed No
SPIN OUTPUT
Check cables, replace coil
Yes
COIL SHORT
Check cables, replace coil
Yes
11
UNLOAD
Press
UNLD
to unload and the text “UNLOADING” shows on the screen. (Note: The vehicle must be stationary.)
DONE
EXIT
DEI1-3C
0%
UNLOAD