Table 18: Axial piston unit malfunction table
Malfunction
Possible cause
Remedy
Excessive temperature of hydraulic
fluid and housing
Excessive inlet temperature at the axial piston
unit
Machine/system manufacturer: inspect system,
e.g. malfunction in the cooler, insufficient
hydraulic fluid in the reservoir
Incorrect setting or malfunction of the pressure
relief valves
Optimize the adjustment of the axial piston
unit pressure relief valves and the pressure
limitation in the hydraulic system
Contact Bosch Rexroth Service
Contact machine/system manufacturer
Axial piston unit worn
Replace axial piston unit, contact Bosch
Rexroth Service