Removal and replacement 47/56
RE 91071-01-B/06.2018, A2FM/A2FE/A2FMT Series 70,
Bosch Rexroth AG
11 Removal and replacement
11.1 Required tools
Removal can be performed using standard tools. No special tools are necessary.
11.2 Preparing for removal
1.
Decommission the entire system as described in the instruction manual for the
machine or system.
– Relieve pressure in the hydraulic system according to the instructions of the
machine or system manufacturer.
– Make sure that the relevant system components are not under pressure or voltage.
2.
Secure the entire system against being re-energized.
11.3 Removal
Proceed as follows to remove the axial piston unit:
1.
Make sure you have the appropriate tools and wear personal protective
equipment.
2.
Allow the axial piston unit to cool down until it can be removed without danger.
3.
For below-reservoir installation, before removing the axial piston unit from the
entire system, seal the connection to the reservoir or drain the reservoir.
4.
Place a drip tray under the axial piston unit to collect any hydraulic fluid that may
leak.
5.
Disconnect the lines and collect the escaping hydraulic fluid in the drip tray.
6.
Remove the axial piston unit. Use a suitable lifting device.
7.
Completely drain the axial piston unit.
8.
Plug all openings.
11.4 Preparing the components for storage or further use
▶
Proceed as described in chapter 6.2 “Storing the axial piston unit” on page 22.