44
en | Programming
Easy Series
F01U087835 | 02 | 2008.10
System Reference Guide
Bosch Security Systems, Inc.
Programming Key Auto Transfer
123
0 = Enable the programming key from the Installer
Menu.
1 = Programming key automatically sends or
receives stored programming data.
1
Point Alarm Verification
124
0 = None
1 = Cross zone
2 = Intelligent threat assessment
3 = Confirmed alarms 1
4 = Confirmed alarms 2
0
Faulted Points Allowed Threshold
125
0 to 8
3
Exit Delay
126
45 to 255 sec
60
Entry Delay
127
30 to 255 sec
30
Exit Time Restart
128
0 = User cannot reset Exit Delay timer
1 = User can reset Exit Delay timer one time
1
Recent Close Enabled
129
0 = Report not sent
1 = Report sent
1
Swinger Bypass Count
131
0-15
1
Auto Protection Level
132
0 = System turns on (unoccupied).
1 = System only turns on (unoccupied) if a
perimeter point is faulted during Exit Delay.
1
System On Order Options
133
1 = "Stay," "Leave," "Custom"
2 = "Stay," "Custom," "Leave"
3 = "Leave," "Stay," "Custom"
4 = "Leave," "Custom," "Stay"
5 = "Custom," "Leave," "Stay"
6 = "Custom," "Stay," "Leave";
1
Cross Zone Timer
134
60 to 3600 sec
120
Clear Alarm Memory
136
0 = By user, 1 = By master user
0
Latching Point and Enclosure Tamper 137
0 = Any user can clear condition
1 = Only the installer can clear condition
0
Latching System Device Tamper
138
0 = Any user can clear condition
1 = Only the installer can clear condition
0
Verbose System Test Enabled
139
0 = Test results announced only at end of all tests
1 = Test results announced after each test
1
Demo Mode
140
0 = Telephone messages heard only on phone
1 = Telephone messages heard on phone and
control centers
2 = Turn announcement of telephone messages over
the control center on or off at the control center
0
Restrict Installer Passcode
142
0 = Master user not needed
1 = Master user needed
0
Test Report Hour
143
0 to 23
Test Report Minute
144
0 to 59
0
Test Report Day of Week
145
0 to 6, where 0 = Sunday and 6 = Saturday
0
Programming Item
Item
Number
Selections
Manuf.
Default