ICP-CC488 |
Installation Guide | 13.0
Access Codes
EN
| 55
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Location
185 to 264
Location
Default
User Code 1
185
2
186
5
187
8
188
0
Priority Level 189
10
User Code 2
190 to 193
15
Priority Level 194
2
User Code 3
195 to 198
15
Priority Level 199
2
User Code 4
200 to 203
15
Priority Level 204
2
User Code 5
205 to 208
15
Priority Level 209
2
User Code6
210 to 213
15
Priority Level 214
2
User Code 7
215 to 218
15
Priority Level 219
2
User Code 8
220
0
221
to
223
15
Priority Level 224
3
User Code 9
225 to 228
15
Priority Level 229
2
User Code 10
230 to 233
15
Priority Level 234
2
User Code 11
235 to 238
15
Priority Level 239
2
User Code 12
240 to 243
15
Priority Level 244
2
User Code 13
245 to 248
15
Priority Level 249
2
User Code 14
250 to 253
15
Priority Level 254
2
User Code 15
255 to 258
15
Priority Level 259
2
User Code 16
260 to 263
15
Priority Level 264
2
13.3 User Code Priority
The installer can assign one of ten different priority
levels to a User Code. Each priority level allows or
restricts a user from performing specific functions.
Table 47: Priority Levels
Priority
Level
Description
0 Arm/disarm
1 Arm
only
2
Arm/disarm and Open/Close Reports
3
Arm only and Close Report
4
Arm/disarm and code to isolate
6
Arm/disarm, code to isolate, and Open/Close
Reports
8
Arm/disarm and Master Code functions
10
Arm/disarm, Master Code functions, and
Open/Close Reports
12
Arm/disarm, Master Code functions, and code
to isolate
14
Arm/disarm, Master Code functions, code to
isolate, and Open/Close Reports
Arm/Disarm
The user can arm and disarm the system. A Closing
Report is sent only after a previous code with the
ability to send an Opening Report disarms the
system.
Arm Only
The user can arm the system but cannot disarm the
system. A Closing Report is sent only after a previous
code with the ability to send an Opening Report
disarms the system.
Open/Close Reports
Open and Close Reports are sent to the monitoring
station when the user disarms and arms the system,
but only if Open/Close Reports is enabled in
Locations 401 and 402 (refer to
Section 15.13
Open/Close Reports
on page 67).
Code To Isolate
If one or more User Codes include this option, the
method of standard isolating is disabled and only a
User Code with this option in its priority level can
isolate zones before arming the system using the
Code to Isolate method. Refer to
Section 3.11 Isolating
Zones
on page 17 for more information.
When priority level 4, 6, 12, or 14 is
assigned to any User Codes, the
Standard Isolating method no longer
operates. Only User Codes with a priority
level of 4, 6, 12, or 14 can isolate zones
using the Code to Isolate method.