ICP-CC488 |
Installation Guide | 10.0
Dialer Reporting Formats
EN
| 46
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Table 43: Point ID Codes
Point ID
Event Description
Event Code
Explanation
Section
Zones 1 to 8
Burglary Zone
130
Burglary
14.3.2
Medical Zone
100
24-Hour Medical
14.3.2
Panic Zone
120
24-Hour Panic
14.3.2
Hold-Up Zone
122
24-Hour Hold-Up
14.3.2
Tamper
Zone
137
24-Hour
Tamper
14.3.2
Burglary
Zone
133
24-Hour
Burglary
14.3.2
Fire
110
24-Hour
Fire
14.3.2
User Specific 1 to 16
Open/Close Report
401
Opening – User #
Closing – User #
15.14
User Specific 1 to 16
Open/Close Report Partitioned
402
Opening – User #
Closing – User #
15.14
User Specific 1 to 16
Partial Close Report
456
Closing – User #
12.2
040
AC MAINS Fail
301
AC Power
15.22
031
Low Battery
309
Battery Test Failure
15.24
User Specific 1 to 16
Codepad Duress
121
Duress Alarm
15.15
041 Codepad
Panic
120
Panic
Alarm
15.16
046
Codepad Fire
110
Fire Alarm
15.17
045 Codepad
Medical
100
Medical
Alarm
15.18
042
Code Retry Limit Exceeded
421
Access Denied
15.26
044
Test Report – Automatic
602
Test Report
15.28
047
Test Report After Siren Reset
602
Test Report
18.5
Zone Specific 1 to 8
Sensor Self Test Failure
307
Sensor Watch
15.5
Zone Specific 1 to 8
RF Device Supervision
15.8
Zone Specific 1 to 8
Trouble
380
Sensor Trouble
15.4
00
AUX Power Supply Fail
300
System Trouble
15.20
User Specific
Walk Test
607
Walk Test Mode
15.2
Zone Specific 1 to 8
Tamper
144
Zone Tamper
15.1
Zone Specific 1 to 8
RF Low Battery
384
RF Low Battery
15.9
001
RF Receiver Fail
355
RF Receiver Jamming
15.10
002
RF Receiver Tamper Switch
15.10
003
RF
Receiver
Failure
15.10
Zone Specific 1 to 8
Bypass
573
Zone Bypass
15.3
Zone Specific 1 to 8
Bypass
572
24-Hour Zone Bypass
15.3
Zone Specific 1 to 8
Bypass
571
24-Hour Fire Zone Bypass
15.3