ICP-CC488 |
Installation Guide | 2.0
Codepad Indicators
EN
| 10
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
1.2.3 Zone
Types
There are thirteen zone types to choose from when
programming zones for the ICP-CC488 Control
Panel. Refer to
Section 14.3 Zone Programming
for
more information.
Table 2:
Zone Types
Type
Description
Type
Description
0 Instant
8 24-Hour
Holdup
1 Handover
9 24-Hour
Tamper
2 Delay-1
10
Reserved
3 Delay-2
11
Keyswitch
4 Reserved
12
24-Hour
Burglary
5 Reserved
13
24-Hour
Fire
6
24-Hour Medical
14
Chime only
7
24-Hour Panic
15
Zone not used
2.0 Codepad Indicators
2.1
ICP-CP508W Eight Zone LED
Codepad
Figure 1: ICP-CP508W Eight Zone LED
Codepad
The codepad is the communications interface
between you and the alarm system. The codepad
allows you to issue commands and offers visual and
audible indications to guide you through general
operation.
The codepad incorporates a number of indicators:
eight zone indicators show the condition of each zone
and four other indicators show general status. These
indicators are described in
Table 3
through
Table 8
on
pages 10 through 11.
Zone Indicators
Table 3:
Zone Indicators
Indicator
Definition
On
The zone is unsealed.
Off
The zone is sealed.
Flashing fast
(0.25 sec. on/
0.25 sec. off)
The zone is in alarm.
Flashing slow
(1 sec. on/1 sec. off)
The zone is manually isolated.
STAY Indicator
The STAY indicator lights when the system is armed
in STAY Mode 1 or STAY Mode 2. The STAY
indicator flashes with the AWAY indicator when you
are in Installer’s Programming Mode or you are
using a Master Code function.
For more information, refer to:
•
Section 3.3
to arm the system in STAY Mode 1.
•
Section 14.3.5
to set zones to be automatically
isolated in STAY Mode 1.
•
Section 3.5
to arm the system in STAY Mode 2.
•
Section 5.1.5
to use the Installer Code to set zones
to be automatically isolated in STAY Mode 2.
•
Section 5.2.6
to use the Master Code to set zones
to be automatically isolated in STAY Mode 2.
Table 4:
STAY Indicator
Indicator
Definition
On
The system is armed in STAY
Mode 1 or STAY Mode 2.
Off
The system is not armed in STAY
Mode 1 or STAY Mode 2.
Flashing
Zone isolating mode or setting STAY
Mode 2 zones.
Flashing once
every 3 sec
Day Alarm status on/off indicator
AWAY Indicator
The AWAY indicator lights when the system is
armed in AWAY Mode. The AWAY indicator
flashes with the STAY indicator when you are in
Installer’s Programming Mode or you are using a
Master Code function.
Refer to
Section 3.1 Arming the System in AWAY Mode
for more information.
Table 5:
AWAY Indicator
Indicator
Definition
On
The system is armed in AWAY Mode.
Off
The system is not armed in AWAY Mode.