Entry Guard Time for STAY Mode
Location
472 to 473
Refer to page 78
Default
0 0
Location 472
Increments of 1 sec (0 to 15 sec)
Location 473
Increments of 16 sec (0 to 240 sec)
Delay Alarm Reporting Time
Location
474 to 475
Refer to page 78
Default
0 0
Location 474
Increments of 1 sec (0 to 15 sec)
Location 475
Increments of 16 sec (0 to 240 sec)
Sensor Watch Time
Location
476 to 477
Refer to page 66
Default
0 0
Location 476
Increments of days (tens digit)
Location 477
Increments of days (units digit)
Codepad Lockout Time
Location
478
Refer to page 79
Default
0
Location 478
Increments of 10 sec
Siren Run Time
Location
479
Refer to page 79
Default
5
Location 479
Increments of 1 minute
Siren Sound Rate (Slow <- Sound -> Fast)
Location
480
Refer to page 79
Default
7
Auto Arming Pre-Alert Time
Location
481
Refer to page 79
Default
1
Location 481
Increments of 5 min
Auto Arming Time
Location
482 to 485
Refer to page 79
Default
0 0 0 0
Location 482
Hour of the day – tens digit
Location 483
Hour of the day – units digit
Location 484
Minute of the day – tens digit
Location 485
Minute of the day – units digit
Auto Disarming Time
Location
486 to 489
Refer to page 79
Default
0 0 0 0
Location 486
Hour of the day – tens digit
Location 487
Hour of the day – units digit
Location 488
Minute of the day – tens digit
Location 489
Minute of the day – units digit
Kiss-Off Wait Time
Location
490
Refer to page 80
Default
3
Location 490
Increments of 500 ms
Speaker Beep Volume
Location
491
Refer to page 80
Default
13
0 No
beeps
15 Loudest
beeps
System Options 1
Location
492
Refer to page 80
1
Bosch Security Systems, Inc. smart lockout allowed
2
Horn speaker monitor
4
Strobe indications for radio arm/disarm
8
Assign button 4 on transmitter to operate STAY
Mode 1
System Options 2
Location
493
Refer to page 81
Default
0
1
Codepad Panic to be silent
2
Codepad Fire to be silent
4
Codepad Medical to be silent
8
Access denied (code retries) to be silent
System Options 3
Location
494
Refer to page 81
1
AC fail after 1 hour (disabled – after 2 min)
2 Ignore
AC
fail
4
Pulse count handover allowed
8
Handover delay to be sequential
System Options 4
Location
495
Refer to page 82
Default
0
1
Panel to power up disarmed (if power reset)
2
Arm/disarm tracking on power up
4
Internal crystal to keep time
8
Night arm station, or RE005 installed
Consumer Options 1
Location
496
Refer to page 82
Default
0
1
Test reports only when armed
2
Test report after siren reset
4
Auto arm in STAY Mode 1
8
STAY indicator to display Day Alarm status
Consumer Options 2
Location
497
Refer to page 83
1
Codepad display extinguishes after 60 sec
2
Single button arming allowed (AWAY/STAY Modes
1 and 2)
4
Single button disarming allowed (STAY Modes 1
and 2)
8
Alarm memory reset on disarm