6 720 643 256 (2010/05)
80
|
Menu settings INSTALLER SETTINGS (for installers only)
US/CA
8.5.10 Parameters for solar optimization
Solar optimization is performed automatically
according to the available solar output.
Calculation of the solar output requires
specification of the installed collector area, the
collector type and the climate zone in which the
system is installed.
Menu: Solar sys parameters > Solar
optimization
Use this menu to set the parameters for solar
optimization.
•
Collector field 1 area
: Use this menu option
to set the installed collector area for collector
field 1.
•
Collector field 1 type
: Use this menu option
to set the installed collector type for collector
field 1.
•
Collector field 2 area
: Use this menu option
to set the installed collector area for collector
field 2 (OPTION A)
Æ
table 8
•
Collector field 2 type
: Use this menu option
to set the installed collector type for collector
field 2.
•
Climate zone
: Use this menu option to set the
climate zone number for the geographical
region in which the system is located.
–
Find the location of your system on the
climate zones map (
Æ
Fig. 27) and enter
the climate zone number.
–
If your location is not shown on the map,
leave the number as it is (default setting is
90).
•
DHW optimization
: This parameter can also
be set on the main menu under
Solar
. A
detailed description can be found on page 51.
•
Heating circuit 1 optimization
: This
parameter can also be set on the main menu
under
Solar
. A detailed description can be
found on page 51.
•
Heating circuit 2 optimization
: This
parameter can also be set on the main menu
under
Solar
. A detailed description can be
found on page 51.
For menu structure and adjustment ranges
Æ
page 62.
Collector
type
Gross collector area in sq.ft.
(m
2
)
FKT-1
26 (2.4)
FKC-1
26 (2.4)
SKS 4.0
26 (2.4)
SKN 3.0
26 (2.4)
Tab. 8
Gross collector areas