6 720 643 256 (2010/05)
MAIN MENU settings
|
41
US/CA
Menu: Heating > Program > View
B
Shows switch points and associated
operating modes for
All days
,
Mon - Fri
,
Sat +
Sun
or the individual day of the week as a
segment pattern.
For menu structure and adjustment ranges
Æ
page 33.
6.2.2 Temperature levels for operating modes
and heating rate
Menu: Heating > Parameter
Use this menu to permanently set the
temperature levels for the 3 operating modes
(
Comfort
/
Economy
/
Frost
) and the
heating rate to suit your personal preferences
and your home.
Menu: Heating > Parameter > Heating circuit
Use this menu to select the heating circuit for
which you would like to set each of the operating
modes:
•
Heat-up speed
: Use this menu option to set
the required heating rate for the
Heating
circuit 1
and/or
Heating circuit 2
:
–
Economy
= The building is heated up
slowly, thus saving energy.
–
Normal
= The building is heated up at the
“normal” rate.
–
Fast
= The building is heated up quickly,
thus providing maximum comfort.
For menu structure and adjustment ranges
Æ
page 34.
Menu: Heating > Parameter > Heating circuit >
Heating levels
Use this menu to set the desired room
temperature for each of the operating modes of
the
Heating circuit 1
and/or
Heating circuit 2
:
•
Comfort
= maximum required temperature
(e.g. when the living space is occupied and
occupants require a comfortable room
temperature).
•
Economy
= medium required temperature
(e.g. when a lower temperature is sufficient or
when the home is empty or everyone is in bed
and you do not want the house to cool down
too much).
•
Frost
= minimum required temperature
(e.g. when the home is empty or everyone is in
bed and it is OK for the house to cool down).
Consider any pets and plants.
For menu structure and adjustment ranges
Æ
page 34.