6 720 643 256 (2010/05)
54
|
Viewing information
US/CA
Domestic hot water
–
–
Operating mode
DHW single charge | Auto
ON | Auto OFF | Vacation -
Auto | Vacation ON |
Vacation OFF
Current operating mode or special mode for
domestic hot water with combi boiler.
DHW single charge |
Thermal disinfection |
Auto | Vacation - Auto |
Vacation 60 °F (15 °C)
Current operating mode or special mode for
domestic hot water tank.
Desired DHW temperature
140 °F (60 °C)
Hot water temperature required by controls.
Current DHW temperature
104 °F (40 °C)
Current measured hot water temperature.
DHW status
Running | Off
Current status of hot water system.
Last thermal disinfection
Completed | Cancelled |
Running
Status of last thermal disinfection.
Customer service
Only available if the Cust service address in the
INSTALLER SETTINGS has been changed.
Telephone number
(Telephone number)
Telephone number of installer (system installer).
Name
(Name)
Name of installer (system installer).
Solar
– –
Standard system
–
Menu for basic system component of solar thermal
system.
T1: Temperature of
collector field 1
176.0 °F (80.0 °C)
Temperature measured by collector temperature
sensor (T
1
).
T2: Temp at bottom of
solar tank
132.2 °F (55.7 °C)
Temperature measured at lower tank temperature
sensor (T
2
) in the solar tank.
SP: Collector field 1
pump status
Running | Off
Status of solar pump (SP).
Collector field 1 shut
down
Yes | No
Shows whether there has been an emergency
shutdown of the solar pump (SP) due to the
collectors overheating (T
1
).
Solar tank status
Fully charged | Partially
charged
Charge status of solar tank.
SP: Collector field 1
pump run time SP:
Collector field 1 pump
run time
12463hr
Hours of duty of the solar pump (SP) since
commissioning.
Heating assistance
–
Menu for the system part solar central heating
boost.
T3: Tank temp at heating
return
113.2 °F (45.1 °C)
Temperature measured at lower tank temperature
sensor (T
3
) in the solar combi tank.
T4: heating return
temperature
96 °F (35.5 °C)
Heating return temperature measured at the
temperature sensor (T
4
).
Menu structure INFO
Display (example)
Description