Dinion IP
| Installation Manual
Caution
Do not interrupt the firmware installation for any reason! Interruption may
lead to faulty coding of the Flash EPROM. This can result in the unit no
longer being addressable, requiring it to be replaced.
Note
A firmware update resets all camera parameters to their factory default
values. If you wish to retain the old values first save the configuration by
performing a configuration download. After the firmware update you can
reload your parameter values by performing a configuration upload.
To update the firmware:
– First, save the update file to the hard disk.
– Enter the full path for the update file in the field or click
Browse...
to locate
and select the file.
– Click
Upload
to begin transmission to the unit. The progress bar allows you to
monitor the transfer.
Note
Installing new firmware and reconfiguring the camera takes several
minutes.
The new firmware is unpacked and the Flash EPROM is reprogrammed. The
time remaining is shown by the message going to reset
Reconnecting in ...
seconds. After the upload is completed successfully, the unit will restart
automatically.
If the operating status LED lights up red, the upload has failed and must be
repeated. To perform the upload, you must switch to a special page:
– In the address bar of your browser, after the unit IP address enter
/main.htm
(for example
192.168.0.80/main.htm
).
– Repeat the upload.
Configuration download
You can save configuration data for the camera to a computer and load saved
configuration data from a computer to the unit.