Partition name
You can enter a new name for the partition.
Video input
The number of the video input is displayed for information purposes.
• Select the required data stream from the list field.
Type of recording
Select the required recording type.
In the case of ring mode the recording proceeds continuously. If the maximum
hard drive space has been reached, the oldest recordings are automatically
overwritten.
In the case of linear mode the recording proceeds until the entire hard drive
space is full. The recording is then stopped until old recordings have been
deleted.
Recording profile
Select the profile that is to be active during recording. You can view and modify
the parameters for the profile (see “Encoder Settings” on page 39).
Note
The recording profile can deviate from the standard setting Active profile
for the video input set and is only used during an active recording.
Number of alarm tracks
Select the number of alarm tracks to be used in the partition. One alarm event
can be recorded in each alarm track. Accordingly, the number of alarms entered
can be recorded and archived. A partition can contain a maximum of 128 alarm
recordings.
If the option ring mode is set for a partition, the latest alarm recordings are
always saved in the preset number. If the option linear mode is selected, the
recording is stopped as soon as the total number of alarm tracks has been
recorded.