70
en | Default Configuration
DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09
Installation Guide
Bosch Sicherheitssysteme GmbH
Pre-alarm time [sec.]:
Select the pre-alarm time for the alarm and motion
recording.
Note:
The maximum pre-alarm time is 1800 seconds. The pre-
alarm time depends on the recording rate of the MPEG4
device's pre-alarm recording. A maximum of 3600 images
can be recorded for each pre-alarm and by each camera.
5
Alarm recording
Make the settings for alarm recording.
Stream
Select the stream for the MPEG4 device (Stream 1 or
Stream 2).
Audio
Activate this check box if audio is also to be recorded.
Post-alarm time [secs.]:
Enter the post-alarm time.
Note:
The maximum post-alarm time is 999 seconds. The default
setting is 0 seconds.
6
Continuous recording
Make the settings for continuous recording.
Stream
Select the stream for the MPEG4 device (Stream 1 or
Stream 2).
Audio
Activate this check box if audio is also to be recorded.
7
Delete old video
Activate this check box to automatically delete data after a
specified number of days.
Older than [days]:
Enter the number of days after which data should be
deleted.
Example
: 3 means that all data older than 3 days is
automatically deleted.
Delete protected data:
Check box is activated: Protected data is automatically
deleted after a specified number of days.
Check box is not activated: protected data is not
automatically deleted.
8
Default settings
Click the button to see the default settings.
9
Copy settings to other
time periods...
Copies all tabs from the selected time period with all the
settings they contain into other time periods.
Click the button. A dialog box opens where you can select
the time periods.
10
Save
The entries are saved.