130
en | Connections
DiBos/DiBos Micro
F.01U.033.308 | V7 | 2009.09
Installation Guide
Bosch Sicherheitssysteme GmbH
9.6
Connecting an ATM (Serial)
A maximum of four customer-operated ATMs or three customer-operated ATMs and one
access control system can be connected to the video system via an interface processor.
The following ATM connection variants are possible:
Variant 1:
The customer-operated ATMs are not far from the video system. The video system and
interface processor, as well as the interface processor and the ATMs, can be connected
together in such a way that the distance between each of them is less than 15 m.
Possible solution:
Connection of each ATM is made directly at the interface processor and is ATM-specific. The
distance between the video system and the interface processor, as well as the distance
between the interface processor and the ATMs, is a maximum of 15 m.
Connection principle:
Connection details:
1
Video system
3
Interface processor
2
Max. 15 m
4
ATM1 - ATM4
1
Video system
4
Interface processor
2
COM x
5
ATM1 - ATM4
3
Connection cable, 9-pin
1
2
3
2
4
E4
E3
PC
E2
E1
5
3
4
1
2