DiBos/DiBos Micro
Connections | en
129
Bosch Sicherheitssysteme GmbH
Installation Guide
F.01U.033.308 | V7 | 2009.09
9.3
Connecting VSCom 200 H (Interface Expansion)
When retrofitting the interface expansion card, the following installation must be carried out.
1.
Switch off the computer and insert the interface expansion card in the appropriate
computer slot.
2.
Reboot the computer.
3.
Log on as Administrator.
4.
The system automatically recognizes the interface expansion card.
9.4
Connecting External Hard Disks
An SCSI controller must be installed in order to connect the external hard disk housing. The
type and number of hard disks that can be connected can be found in the price list.
External hard disks must be switched on before booting the PC.
9.5
Connecting a Malfunction Relay
The malfunction relay is connected to a relay output. It must be activated in the configuration
(see
Section 6.5.2 Configuring Relay Outputs
).
The following events are signaled by the malfunction relay.
–
The camera does not deliver a video signal
–
The logbook cannot be created or written
–
The images could not be recorded by the database server
–
Database server could not be started
–
Hard disk failure: Drive X deactivated, drive X not deactivated
–
The hard disk is full (protected image data)
–
Internal database error
–
Device could not be started
–
Grabber card not working
–
Export video scheduler error
–
Reference image check failed
To be carried out by authorized personnel only!
NOTICE!
Only the card type VSCom 200 H PCI may be used.
NOTICE!
Only the following card type may be used as an SCSI controller: LSI Logic 320 MB Ultra Wide
68 PIN HD SYM 21320.
CAUTION!
Do not position the SCSI cable near to a power cable. This influences the transmission rate
and may cause the connection to be interrupted.