Error messages
What the Carephone 52+
says
Meaning
Power failure
Power failure. The indicator lamp in the activity
monitor reset button flashes.
Check the power connection of the Carephone
52+.
Power failure ended
When power is restored
Unit battery empty
The Carephone 52+ backup battery no longer has
its full capacity. Contact the social alarm call
centre or customer service.
Line failure
The connection to the telephone network has
been lost. Check the plug on the unit and the
telephone jack.
Transmission failure
An activated emergency call cannot be sent
despite 15 repeated dialling attempts.
Press the S-button to stop the error message
announcement. Contact the social alarm moni-
toring centre provider or customer service.
Error zero-one
External signal detected
The indicator lamp in the activity monitor reset
button continues to flash until the message has
reached the centre.
Failure two-X:
Transmitter battery empty
(X is the transmitter number)
Failure three-X:
Radio transmission monitoring faulty. The indica-
tor lamp in the activity monitor reset button con-
tinues to flash until the message has reached the
centre.
(X is the transmitter number)
Table 10.5