The following dip switch settings pertain to AutoDome
Versions 5.00 and newer.
*Default position for all switch settings is OFF.
Figure 1A S105 Dip Switch Settings
Photo 1C Set the address switch
1.4
Reconnect the top plate cable, then replace the top plate
and gasket (see PHOTO 1D). Align the ribs on the bot-
tom of the top plate with the matching openings in the
housing, then firmly tighten the four (4) screws.
Photo 1D Replace top plate
1.5
To avoid confusion during installation, write the camera
address on masking tape and stick it to the dome, as
shown in PHOTO 1E.
The dome is now ready to be installed, using an
appropriate AutoDome mount.
Photo 1E Write camera address
Installation should be performed by qualified service
personnel only, in accordance with the National
Electrical Code or applicable local codes. Refer to the
appropriate installation section.
The AutoDome can be mounted to a wall, mast (pole), roof,
pipe, or a corner mount once the appropriate mount has been
installed. Each mount includes its own mounting instructions.
Mounts must be properly and securely mounted to a
supporting structure capable of sustaining the unit
weight.**Use care when selecting mounting hardware
(not supplied) for installation. The mounting surface
and unit's weight should be carefully considered.
The following instructions reference a 120/230 VAC
pendant wall plate installation mounted to an existing structure.
The instructions assume the safety cable, power, video, and con-
trol cables have already been properly installed.
**Refer to mounting instructions.
Section 1
Switch # Function
Position
Selection
1
RESERVED
2
Serial Mode Selection
ON
OFF
RS-485
RS-232*
3
RESERVED
4
Low Pressure Detection
ON
OFF
Pressurized Dome
Non-Pressurized
Dome*
Address
Switches
S105 Dip Switches