EN
© 2005 Bosch Security Systems
Page 11 of 40
SECTION 2
In-ceiling AutoDome
Installation Instructions
2.1
Before installing this unit, install and wire the
In-ceiling Backbox (LTC 7490), following the instructions
provided with that unit.
Carefully remove the AutoDome from the box. Save all
packing material, to be used for setup and transport of
the camera and dome.
If an item appears to have been damaged in shipment,
notify the shipper. If any items are missing, notify your
Bosch Sales or Customer Service Representative at the
location nearest you. See our Web site at
www.boschsecurity.com.
Photo 2A In-ceiling AutoDome
2.2
To use FastAddress, skip to STEP 2C. Otherwise, set the
address switch as shown. Setting address selector to 0000
causes the AutoDome to respond to ALL messages regardless
of address (NOT RECOMMENDED); otherwise, the unit
only responds to commands issued for that address.
If using RS-232/RS-485 Communications:
The unit is shipped with the RS-232/RS-485 Baud Rate
set to 9600. This rate can be changed via the
COMMUNICATIONS SETUP menu
(see SECTION 6).
The following settings pertain to AutoDome versions 5.00
and newer:
*Default position for all switch settings is OFF.
Figure 2A S105 Dip Switch Settings
Photo 2B S105 Dip switch and Address selector
Section 2
Switch # Function
Position
Selection
1
RESERVED
2
Serial Mode Selection
ON
OFF
RS-485
RS-232*
3
RESERVED
4
Low Pressure Detection
ON
OFF
Pressurized Dome
Non-Pressurized
Dome*
S105 Dip Switch
Address Switch