48/56
Maintenance and repair
Bosch Rexroth AG
, MIT: HD 2/H, 3 842 358 796/2015-01
10.4.2
Replace damper for rotary table
Fig. 29:
358 732-17
A
!
1
2
3
0
4
ok
n. ok
Klüber
Struktovis
GHD 0,5 g
2x
SW4
M
D
=7 Nm
M
D
=8,7 Nm
SW24
M
D
=8,7 Nm
SW22
Replace damper for rotary table (example shown here size 2 180°)
Please note:
• Perform the replacement
at the upper end position
of the lift rotate unit.
• The rotating cylinder
must be depressurized
(vented). The rotary
table must be rotated for
disassembly/assembly.
1.
Remove the damper (A)
2.
Install the new damper.
3.
Adjust the damper by
screwing in/out of the
damper housing so
that the rotary table
is parallel to the belt
section at the end
position (see chapter 8.4
“Check and adjust
the rotation angle of
the lift rotate unit” on
page 37).
4.
Lubricate the load
adapter.
Please note:
Repair of the lift rotate
unit must be carried out by
Rexroth!
358732_2015_01_EN.indd 48
358732_2015_01_EN.indd 48
29.05.2015 08:33:01