26/56 Installation
Bosch Rexroth AG
, MIT: HD 2/H, 3 842 358 796/2015-01
7.5.6
Install parts for WT 2 control (size 3)
Fig. 13:
358 732-21
S1
l
T
+≥70
36
S2
17
B
A
S3
0,3
Install separator stop and proximity switches (example shown here size 3 180°)
Required accessories
• Separating stop VE 2, see
catalog TS 2plus.
• Proximity switch
IEC/EN 60947-5-2-2004,
3 842 537 995.
1.
Install the two separating
stop (2 x VE 2) and the
proximity switches (S 1,
S 2, S 3) on the section
profi le.
Check functionality
1.
Starting position:
Pre-separating stop (A)
open main separating
stop (B) closed; lift
rotate unit in the lower
end position
2.
S 1 actuated by passing
WT2: VE (A) closes.
3.
S 2 actuated by passing
WT2: Cylinder moves to
upper end position, WT2
is lifted.
4.
Switch upper end
position actuated:
Rotation 90° or 180°.
5.
Rotation end position
reached: If required start
operation.
6.
If required, complete
operation, external
signal: Cylinder moves to
lower end position, WT2
is raised.
7.
Switch lower end
position actuated: main
separating stop (B)
opens.
8.
S 3 actuated by passing
WT2: main separating
stop (B) closes,
pre-separating stop (A)
opens (starting
position).
358732_2015_01_EN.indd 26
358732_2015_01_EN.indd 26
29.05.2015 08:32:55