16.2 Ambient conditions
• The transfer systems are designed for stationary use in weather-protected areas.
• Working
temperature:
+5 °C to +40 °C
–5 °C to +60 °C at 20% reduced load
• Storage temperature –25 °C to +70 °C
• Relative humidity
5% to 85%, non-condensing
• Air pressure
> 84 kPa corresponds to an altitude < 1400 m above sea level
• Permissible load capacity of fl oor: 1000kg/m
2
• At altitudes > 1400 m, the load values of the electric drives are reduced by 15%.
• Avoid molds, fungi and rodents, and other pests.
• Installation and operation in the immediate vicinity of industrial equipment with
chemical emissions is not permitted.
• Do not install and operate in the vicinity of sand or dust sources.
• Do not install and operate in areas which are regularly jarred by high forces caused
by presses or heavy machinery, for example.
• Resistant to many conventional substances used in the manufacturing sector, such
as water, oil, grease, and detergents. If you are unsure about resistance against
certain chemicals such as test oil, doped oils, aggressive detergents, solvents,
or brake fl uid, we recommend that you consult with your specialized Rexroth
representative.
• Prolonged contact with highly acidic or alkaline reacting substances must be
avoided.
16.3 Pneumatics
• Oiled compressed air or unlubricated, fi ltered, dry.
• Operating pressure:
4 to 6 bar
• Solid materials
– Size of particles
– Amount of particles
≤ 5 µm
≤ 5 mg/m
3
(Class 6 according to ISO 8573-1:2010)
(Class 6 according to ISO 8573-1:2010)
• Water content
– Pressure dew point
1
)
≤ +3 °C
(Class 4 according to ISO 8573-1:2010)
1
) The pressure dew point should be at least 15 °C below the ambient temperature.
• Oil content
– Oil quantity
≤ 1 mg/m
3
(Class 3 according to ISO 8573-1:2010)
358732_2015_01_EN.indd 54
358732_2015_01_EN.indd 54
29.05.2015 08:33:01
29.05.2015 08:33:01